WEBVTT 1 00:00:03.592 --> 00:00:04.979 A pump has a reliability 2 00:00:04.979 --> 00:00:05.704 figure. 3 00:00:05.704 --> 00:00:06.929 So does a valve, a 4 00:00:06.929 --> 00:00:09.262 gearbox, a heat exchanger. 5 00:00:09.279 --> 00:00:10.317 None of that tells you 6 00:00:10.317 --> 00:00:11.654 whether the system they belong 7 00:00:11.654 --> 00:00:13.654 to will finish the shift. 8 00:00:13.654 --> 00:00:16.017 A reliability block diagram turns 9 00:00:16.017 --> 00:00:17.954 those separate component figures 10 00:00:17.954 --> 00:00:19.704 into one system figure, and 11 00:00:19.704 --> 00:00:21.962 shows exactly how they combine. 12 00:00:24.225 --> 00:00:25.575 Every block in that diagram 13 00:00:25.575 --> 00:00:26.588 has to sit somewhere in 14 00:00:26.588 --> 00:00:27.750 your plant's own equipment 15 00:00:27.750 --> 00:00:28.850 hierarchy. 16 00:00:28.850 --> 00:00:30.088 Not the whole plant, and 17 00:00:30.088 --> 00:00:31.550 not a single bolt: the 18 00:00:31.550 --> 00:00:33.450 equipment class or unit level, 19 00:00:33.450 --> 00:00:35.088 a pump, a valve, a 20 00:00:35.088 --> 00:00:36.420 heat exchanger. 21 00:00:36.425 --> 00:00:38.738 That's normally where a CMMS 22 00:00:38.738 --> 00:00:41.100 already holds reliability data, so 23 00:00:41.100 --> 00:00:42.225 it's where a first system 24 00:00:42.225 --> 00:00:43.770 diagram should start. 25 00:00:46.458 --> 00:00:48.596 Chain components in series, and 26 00:00:48.596 --> 00:00:50.783 system reliability only ever goes 27 00:00:50.783 --> 00:00:52.303 down, never up. 28 00:00:54.592 --> 00:00:56.704 Run several identical units in 29 00:00:56.704 --> 00:00:59.167 active parallel, and requiring fewer 30 00:00:59.167 --> 00:01:00.742 of them to succeed lifts 31 00:01:00.742 --> 00:01:02.587 reliability sharply. 32 00:01:05.258 --> 00:01:06.658 Keep a spare in standby 33 00:01:06.658 --> 00:01:08.096 instead of running it, and 34 00:01:08.096 --> 00:01:09.558 a switch has to start 35 00:01:09.558 --> 00:01:10.721 that spare the moment the 36 00:01:10.721 --> 00:01:12.408 duty unit fails. 37 00:01:12.408 --> 00:01:13.846 That switch is part of 38 00:01:13.846 --> 00:01:15.946 the reliability model too, not 39 00:01:15.946 --> 00:01:17.278 a free connection. 40 00:01:19.925 --> 00:01:21.288 Every one of those formulas 41 00:01:21.288 --> 00:01:23.000 assumes each component fails 42 00:01:23.000 --> 00:01:24.825 independently of the others. 43 00:01:24.825 --> 00:01:26.375 Trace one real failure down 44 00:01:26.375 --> 00:01:28.388 to its component, its mechanism 45 00:01:28.388 --> 00:01:29.825 and its cause, and that 46 00:01:29.825 --> 00:01:31.570 assumption can break. 47 00:01:31.588 --> 00:01:33.788 A shared inlet screen bypassing 48 00:01:33.788 --> 00:01:35.413 can drive the same abrasive 49 00:01:35.413 --> 00:01:37.675 wear mechanism into two nominally 50 00:01:37.675 --> 00:01:39.312 independent pumps at the same 51 00:01:39.312 --> 00:01:41.470 time, for the same reason. 52 00:01:44.125 --> 00:01:45.500 Here is the same method, 53 00:01:45.500 --> 00:01:46.825 run end to end, on 54 00:01:46.825 --> 00:01:49.225 one illustrative system: a screen, 55 00:01:49.225 --> 00:01:50.600 a duty and standby pump 56 00:01:50.600 --> 00:01:52.562 pair, four heat exchangers, and 57 00:01:52.562 --> 00:01:53.970 a discharge valve. 58 00:01:53.975 --> 00:01:55.762 Screen, pump pair and valve 59 00:01:55.762 --> 00:01:56.950 stay fixed. 60 00:01:56.950 --> 00:01:58.200 Requiring three of the four 61 00:01:58.200 --> 00:02:00.125 heat exchangers, for full rated 62 00:02:00.125 --> 00:02:01.775 production, gives a system 63 00:02:01.775 --> 00:02:04.920 reliability of 0.973. 64 00:02:07.925 --> 00:02:09.225 Requiring only one of the 65 00:02:09.225 --> 00:02:10.750 four, just to avoid an 66 00:02:10.750 --> 00:02:13.038 emergency trip, lifts that same 67 00:02:13.038 --> 00:02:16.545 physical hardware to 0.987. 68 00:02:18.817 --> 00:02:20.129 Same components. 69 00:02:20.129 --> 00:02:21.504 Same connections. 70 00:02:21.504 --> 00:02:22.942 Two different questions, two 71 00:02:22.942 --> 00:02:25.292 different, both correct, answers. 72 00:02:25.292 --> 00:02:26.404 That is what this page 73 00:02:26.404 --> 00:02:28.104 teaches, with the full working 74 00:02:28.104 --> 00:02:29.762 shown end to end. 75 00:02:31.658 --> 00:02:33.371 And it's the same series, 76 00:02:33.371 --> 00:02:35.821 parallel, and standby arithmetic 77 00:02:35.821 --> 00:02:37.346 that turns your own equipment 78 00:02:37.346 --> 00:02:39.483 hierarchy, and the failure data 79 00:02:39.483 --> 00:02:41.483 behind it, into one system 80 00:02:41.483 --> 00:02:43.528 figure your team can defend.